TriStar MPPT
Objects and Definitions
Data
This is the complete list of data objects that can be accessed using the Data
dropdown on the dashboard
Object | Description | Type | Symbol |
---|---|---|---|
adc_vb_f_med |
Battery voltage, filtered | volts | V |
adc_vbterm_f |
Batt. Terminal voltage, filtered | volts | V |
adc_vbs_f |
Battery Sense voltage, filtered | volts | V |
adc_va_f |
Array voltage, filtered | volts | V |
adc_ib_f_shadow |
Battery current, filtered | amps | A |
adc_ia_f_shadow |
Array current, filtered | amps | A |
adc_p12_f |
12 volt supply, filtered | volts | V |
adc_p3_f |
3 volt supply, filtered | volts | V |
adc_pmeter_f |
MeterBus voltage, filtered | volts | V |
adc_p18_f |
1.8 volt supply, filtered | volts | V |
adc_v_ref |
reference voltage | volts | V |
T_hs |
Heatsink temperature | celsius | °C |
T_rts |
RTS temperature | celsius | °C |
T_batt |
Battery regulation temperature | celsius | °C |
adc_vb_f_1m |
Battery voltage, filtered | volts | V |
adc_ib_f_1m |
Charging current, filtered | amps | A |
vb_min |
Minimum battery voltage | volts | V |
vb_max |
Maximum battery voltage | volts | V |
hourmeter |
hourmeter | hours | h |
fault |
Controller faults bitfield | array | |
alarm |
Alarms | array | |
dip_switch |
DIP Switch Settings at Power On | array | |
led_state |
State of LED indicators | string | |
charge_state |
Charging state | string | |
vb_ref |
Target regulation voltage | volts | V |
Ahc_r |
Ah Charge Resettable | amp-hours | Ah |
Ahc_t |
Ah Charge Total | amp-hours | Ah |
kWhc_r |
kWhr charge resettable | kilowatt-hours | kWh |
kWhc_t |
kWhr charge total | kilowatt-hours | kWh |
power_out_shadow |
Output Power | watts | W |
power_in_shadow |
Input Power | watts | W |
sweep_Pin_max |
Max. Power of last sweep | watts | W |
sweep_vmp |
Vmp of last sweep | volts | V |
sweep_voc |
Voc of last sweep | volts | V |
vb_min_daily |
Minimum Battery Voltage (daily) | volts | V |
vb_max_daily |
Maximum Battery Voltage (daily) | volts | V |
va_max_daily |
Max. daily input voltage | volts | V |
Ahc_daily |
Ah Charge (daily) | amp-hours | Ah |
Whc_daily |
Total Wh charge daily | watt-hours | Wh |
flags_daily |
Flags Bitfield (daily) | array | |
Pout_max_daily |
Max. Power Out, daily | watts | W |
Tb_min_daily |
Min. battery temp. daily | celsius | °C |
Tb_max_daily |
Max. battery temp. daily | celsius | °C |
fault_daily |
Faults, daily | array | |
alarm_daily |
Daily alarms | array | |
time_ab_daily |
cumulative time in absorption daily | seconds | s |
time_eq_daily |
cumulative time in equalize daily | seconds | s |
time_fl_daily |
cumulative time in float daily | seconds | s |
Ib_ref_slave |
Battery current regulation override | amps | A |
vb_ref_slave |
Battery voltage regulation override | volts | V |
va_ref_fixed |
Array V fixed voltage target | volts | V |
va_ref_fixed_pct |
Array V % of Voc voltage target | percentage | % |
EV_absorp |
Absorption Voltage @ 25ºC | volts | V |
EV_float |
Float Voltage @ 25ºC | volts | V |
Et_absorp |
Absorption time | seconds | s |
Et_absorp_ext |
Absorption extension time | seconds | s |
EV_absorp_ext |
absorp. Extension threshold voltage | volts | V |
EV_float_cancel |
Voltage to cancel float | volts | V |
Et_float_exit_cum |
Exit Float Time | seconds | s |
EV_eq |
Equalize Voltage @ 25ºC | volts | V |
Et_eqcalendar |
Days Between EQ Cycles | days | d |
Et_eq_above |
Equalize Time Limit above EV_reg | seconds | s |
Et_eq_reg |
Equalize Time Limit at EV_eq | seconds | s |
Et_batt_service |
Battery service timer | days | d |
EV_tempcomp |
temp. compensation coefficient | volts | V |
EV_hvd |
Battery high voltage disconnect | volts | V |
EV_hvr |
Battery high voltage reconnect | volts | V |
Evb_ref_lim |
Battery Reference Charge Voltage Limit | volts | V |
ETb_max |
max. temp comp limit | celsius | °C |
ETb_min |
min. temp comp limit | celsius | °C |
EV_soc_g_gy |
LED Green to Green&Yellow Limit | volts | V |
EV_soc_gy_y |
LED Green&Yellow to Yellow Limit | volts | V |
EV_soc_y_yr |
LED Yellow to Yellow&Red Limit | volts | V |
EV_soc_yr_r |
LED Yellow&Red to Red Flashing Limit | volts | V |
Emodbus_id |
Modbus ID | ||
Emeterbus_id |
Meterbus ID | ||
EIb_lim |
Battery Current Limit | amps | A |
EVa_ref_fixed_init |
Array V fixed target voltage | volts | V |
EVa_ref_fixed_pct_init |
Array V fixed target V (% of Voc) | volts | V |
Ehourmeter |
Hourmeter | hours | h |
EAhc_r |
Ah Charge Resettable | amp-hours | Ah |
EAhc_t |
Ah Charge Total | amp-hours | Ah |
EkWhc_r |
kWh charge resetable | kilowatt-hours | kWh |
EkWhc_t |
kWh charge total | kilowatt-hours | kWh |
EVb_min |
Battery Voltage Minimum | volts | V |
EVb_max |
Battery Voltage Maximum | volts | V |
EVa_max |
Array Voltage Maximum | volts | V |
Etmr_eqcalander |
Days Since Last Equalize | days | d |
Etmr_batt_service |
battery service timer | days | d |
Action
Object | Description |
---|---|
eq |
Trigger equalize charge |
charge_off |
Turn charge on |
charge_on |
Turn charge off |
Ah_r |
Reset Ah resettable |
Ah_t |
Reset Ah total |
kWh_r |
Reset kWh resettable |
faults |
Reset faults |
alarms |
Reset Alarms |
EEPROM |
Reset EEPROM |
kWh_t |
Reset kWh total |
Vb |
Reset battery min and max |
single_phase |
Test a single phase (test mode only) |
reset |
Reset controller |
2 Hour Logs
These objects are logged every 2 hours.
Objects:
power_out_shadow
power_in_shadow
adc_vbterm_f
adc_va_f
adc_ib_f_shadow
adc_ia_f_shadow
T_hs
charge_state
sweep_vmp
sweep_voc
vb_ref
Daily Logs
These objects are logged once every day.
Objects:
hourmeter
vb_min_daily
vb_max_daily
Ahc_daily
Tb_min_daily
Tb_max_daily
Pout_max_daily
time_ab_daily
time_eq_daily
time_fl_daily
Alerts
These objects are scanned every few seconds and alerts will be sent as soon as any critical issues are detected.
Objects:
charge_state
fault
alarm